Re: PM notification-IW22
This date is set by the system when the notification is closed (NOCO). I don't think it can be manually changed without some form of development. Also be aware that this data may be used in PMIS. PeteA
View ArticleRe: order creation with reference to PAM notification
Hi Vivek, The costs aren't maintained against the equipment master record as it would seem that you have worked out. I'm afraid I have no documentation which I have used for setting up PAM it was all...
View ArticleRe: How to create a LINK in BoM between two different plant ?
Thank you Also Elvin, BoM Group is also an very usfull tool That I will use for group BoM changes !
View ArticleRe: Indicator: schedule automatically
Hello Sebastian, Thank you. I have tried it but this enhancement doesn't allow to modify the schedule indicator. And I'm not able to find any other user exit where this field is available during...
View ArticleRe: PM Order Settlement
Check with your FICO consultant on Field Settings variant maintained in that G/L Account. Also check the correctness of current postings happening now.
View ArticleRe: PM Order Settlement
Thank you Maheswaran. So you believe that the cost center must not be entered together with the PM order, right?So all costs should be posted on the PM order and then to be settled. However, i cannot...
View ArticleRe: Custom workflow requirement-during user status change in Orders
Hi Yogesh, Table UST10S stores Profile , authorization object (like B_USERSTAT) and authorization value. However it is coded not end user friendly. You can find in su03-->click authorization...
View ArticleRe: order creation with reference to PAM notification
Hi Vivek, Have you maintained values in the Rental Price and Price/ Unit fields in the configuration maintained above? I believe these are what are causing your error. I did not use settlement when...
View ArticleCut over template for Maintenance plans
Hi,Friendsis there any cut over template for single cycle and strategy maintenance plans if there how to make it? Thanks&Regards,Kumar
View ArticleBasis of picking MRP area, as viewed in MD04
Hi Experts, I am creating PM order with components. Now I get reservation number. The reservation is also reflected in MD04 list with some MRP area filled.I want to know what is the basis of picking...
View ArticleArchiving Functional Location
Hello Experts, We are facing the issue in archiving the Functional Location. We have created some functional locations, but by mistake the structure indicator is interchanged in between the functional...
View ArticleRe: Basis of picking MRP area, as viewed in MD04
Hi Rajesh, I have a difficulty, to understand your question.OMIZ is the configuration place, where you can manage the MRP areas with plants. Probably the value is picked up in MD04, based on te plant...
View ArticleRe: Archiving Functional Location
VT, You can relabel functional locations this allows you to also change the Structure Indicator. Check to see if you have activated alternative labelling in the IMG. If you need to reuse an old...
View ArticleRe: Archiving Functional Location
Hi, I expect you are using alternative labelling. In this case, when archiving you need to select the flag 'Archiving with Altern label' as part of the archiving WRITE program. Once archiving is...
View ArticleRe: No status object is available for MPL 27128
Hi Maheswaran, I have implemented the note # 1800596. While implementing its asked us to implement the additional note # 1285238 as well. This additional note # 1285238 contains lot of manual steps and...
View ArticleRe: CHANGING STATUS FROM CLSD TO TECO IN A PM ORDER
Hi, CLSD status of the order can be cancelled by using following process. Open the order in change mode using IW32 transaction.Follow the path as Order --> Function --> Complete --->Cancel...
View ArticleUpdate equipment user status when Classification value changes
We are looking to streamline the recall process within our company. We have a custom equipment classification characteristic which is set when an item needs to be recalled. We also have a user status...
View ArticleRe: Update equipment user status when Classification value changes
Keith You can use user-exit IEQM0003 (Additional checks before equipment update) to check for data inconsistencies between the classification and user-status data. See TCode SMOD for more details.
View ArticleRe: Update equipment user status when Classification value changes
Thanks Pete. I had looked at that but it says that no data can be changed. I could use it to check and stop the equipment record from being saved (along with a relevant message), but it won't...
View ArticleRe: Update equipment user status when Classification value changes
You can set/reset the user-status via this user-exit. There are various development option to do this. But unless you had specific rules, you wouldn't be able to update the class data. PeteA
View Article