Hi Raghuvarun,
The reports mentioned above {RIARCMRP/A/D} support the archiving of measurement documents - not measuring points.
There doesn't appear to be an archiving object for PM measuring points in ECC 6.05 - so presumably archiving of measuring points directly over archiving isn't supported. I note also that the definition of the archiving object for equipment PM_EQUI doesn't list IMPTT (the measuring point table) as a table from which data is archived when an equipment is archived. A quick search in the archiving program RIARCEQA doesn't show any sign of IMPTT. I presume then that measuring points are not indirectly archived when the equipment is archived. There are BADIs provided (ARC_PM_EQUI_DELETE/READ/WRITE)
After measurement documents are deleted using archiving, you can then delete the measuring point associated with the technical object without archiving from within the Maintain Measuring Points: Overview screen of the relevant technical object - Functional Location or Equipment. Follow Edit -> Delete Entry as vemuri santosh kumar mentioned above.
Andrew